Enhancing the hydrothermal performance of plate-fin microchannels heat sink (PFMCHS) promises smaller size and lighter weight, and then improve the heat removal in consequently increase the speed of electronic devices. In this numerical study, an innovative hydrothermal design of PFMCHS is suggested by inserting elliptic pins inside microchannels in different; aspect ratio (AR) of pin, pin number ratio (ψ) in order to optimize the hydrothermal design of this kind of heat sinks. The main objectives of this study are; investigating the effect of pins on the performance of PFMCHS by investigating the best geometry in the pinned-fin MCHS and which is higher, thermal or hydraulic performance of this kind of heat sinks and what is the optimal number of pins numerically and what about the pressure drop penalty in the proposed design, little, modest or high increase. It is seen that the thermal resistance of the pinned fin MCHS is about 50% lower, and pressure drop of it is much higher than that of the (PFMCHS) under the condition of equal wind velocity. Maximum mechanical fan power reduction obtained is about 57% for the pinned fin MCHS with ψ = 1 and Dh = 1 ×10-3 m compared to the corresponding original channel heat sink. To show the overall performance of the two parameters; aspect ratio (AR), pin number ratio (ψ), the overall JF factor is estimated and the concrete findings shows that the best hydrothermal performance is obtained at the greater aspect ratio which is around overall JF = 1.2. In addition, the trend of overall JF is going down with the pin number ratio, starting from 1.2 to 1.15. And the concrete findings show that pinned fin MCHS provides thermal performance of 1.42 times greater than the smooth one under the corresponding conditions when one pin is used in each channel
Experiments were carried out on natural convection heat transfer from longitudinal trapezoidal fins array heat sink subjected to the influence of orientation. A trapezoidal fins heat sink with various orientations tested under a controlled environment. Test results indicate that the sideward horizontal fin orientation yield the lowest heat transfer coefficient. However the sideward vertical fin orientation gave the best performance on the natural cooling. From the experiments Nu is determined as a function of Ra at Pr=0.7 for each orientation with Ra ranging between (1400 and 3900).From the results; Heat transfer coefficient of the sideward vertical fins is higher by (12%) than the heat transfer coefficient of the upward while it is higher than the heat transfer coefficient of the downward by (26%) and by (120%) with the sideward horizontal fins. Orientation affected the temperature distribution along the fins, therefore the temperature along the sideward vertical fins have the best performance with uniform distribution, while in sideward and downward the temperature increased in the positions near the base plate surface because of the complication in moving the heated air.