Anbar Journal of Engineering Science
Login
Anbar Journal of Engineering Sciences
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
    • Reviewers of AJES
  • About
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Journal Insights
    • Peer Review Process
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Open Access
    • Archiving Policy
    • Journal Funding Sources
    • Announcements
    • Contact

Search Results for heat-transfer-enhancement

Article
Numerical Study of Fluid Flow and Heat Transfer over a Bank of Oval-Tubes Heat Exchanger with Vortex Generators

Abdulmajeed A. Ramadhan

Pages: 88-108

PDF Full Text
Abstract

The present work represents a two-dimensional numerical investigation of forced laminar flow heat transfer over a 3-rows oval-tube bank in staggered arrangement with rectangular longitudinal vortex generators (LVGs) placed behind each tube. The effects of Reynolds number (from 250 to 1500), the positions (3 in x-axis and 2 in y-axis) and angles of attack (30o and 45o) of rectangular VGs are examined. The study focuses on the Influence of the different parameters of VGs on heat transfer and fluid flow characteristics of three rows oval-tube banks. The characteristics of average Nu number and skin friction coefficient are studied numerically by the aid of the computational fluid dynamics (CFD) commercial code of FLUENT 6.3. The results showed increasing in the heat transfer and skin friction coefficient with the increasing of Re number and decreasing the relative distance of positions of LVGs. It has been observed that the overall Nuav number of three oval-tubes increases by 10–20.4% and by 10.4–27.7% with angles of 30o and 45o respectively, with increasing in the overall average of skin friction coefficient of three oval-tubes reached to 53% and 72% with two angles used respectively, in comparison with the case without VGs.

Article
Effect of Delta–Winglet Vortex Generators on a Forced Convection Heat Transfer in an Asymmetrically Heated Triangular Duct

Hamid E.Zangana, Adnan A. Abdul-Rassol, Mohanad A. Al-Taher

Pages: 31-44

PDF Full Text
Abstract

An experimental investigation is performed to study the friction factor ( f ) and convection heat transfer coefficient (h) behavior in an asymmetrically heated equilateral triangular duct by using delta–winglets vortex generators which are embedded in a turbulent boundary layer. Two side walls of the heated test section are electrically heated with a constant heat flux, whereas the lower wall is indirectly heated. Reynolds number (Re) is ranged from (23,000) to (58,000). Two sizes and three attack angles of vortex generators are studied here for three cases; single, double, and treble pairs of generators. Each pair was supported in one wall of the test section at the various locations from the leading edge. The indicated results that friction factor ( f )and Nusselt number (Nu) are relatively proportion with the size, number and the inclination angle of the generators. The ( f ) decreases as airflow rate increases whereas Nu number increases. The present data of ( f ) is less than the data of Chegini by about (6.5 %) and overpredicts the data of Altemani by about (1.7 %).

Article
Numerical Investigation of Hydraulic-Thermal Performance for a Double-Pipe Heat Exchanger Equipped with 45°-Helical Ribs

Ahmed K. Mashan, Waleed M. Abed, Mohammed A. Ahmed

Pages: 193-202

PDF Full Text
Abstract

In this paper, the hydraulic-thermal performance of a double-pipe heat exchanger equipped with 45°-helical ribs is numerically studied. The ribbed double-pipe heat exchanger is modelled using three heights (H = 0, 2.5, 3.75, 5 mm) of 45°-helical ribs. Two numbers (4-ribs and 8-ribs) of 45°-helical ribs are attached on the outer surface of the inner pipe of the counter-flow double-pipe heat exchanger and compared with a smooth double-pipe heat exchanger. Three-Dimensional computational fluid dynamics (CFD) model for a laminar forced annular flow is performed in order to study the characteristics of pressure drop and convective heat transfer. In addition, the influence of rib geometries and hydraulic flow behaviour on the thermal performance is system-atically considered in the evaluations. The annular cold flow is investigated with the range of Reynolds numbers from 100 to 1000, with three heights of ribs at the same width (W = 2 mm) and inclined angles of (θ = 45°).The results illustrate that the average Nusselt number and pressure drop increase with an in-creasing number of ribs, the height of ribs and Reynold number, while the friction factor decreas-es with increasing Reynolds numbers. The percentage of averaged Nusselt number enhancement for three rib heights (H = 2.5, 3.75 and 5 mm) at 4-ribs is (34%, 65% and 71%), respectively, While for 8-ribs the enhancement percentage is (48%, 87% and 133%) as compared with the smooth double-pipe heat exchanger at Re = 100. The best performance evaluation criteria of (PEC) at (8-ribs, and H = 5 mm) is 2.8 at Re = 750. The attached 45-helical ribs in the annulus path can generate kind of secondary flows, which enhance the fluid mixing operation between the hot surface of the annular gap and the cold fluid in the mid of the annulus, which lead to a high-temperature distribution. Increasing the height of 45°-helical ribs lead to an increase in the sur-face area subjecting to convective heat transfer.

Article
Performance of a double-pipe heat exchanger with different met-al foam arrangements

Thaer H. Farhan, Obaid T. Fadhil, Hamdi E. Ahmed

Pages: 100-112

PDF Full Text
Abstract

This paper contributes to the field of improving the performance of heat exchangers using metal foam (MF) full-filled and partially/periodically-filled within the gap between the two pipes. The effect of configuration and arrangement of copper MF (15PPI and porosity of 0.95) installed on the outer surface of the inner pipe of a counter-flow double-pipe heat exchanger on the thermal and hydraulic performance was studied experimentally. The test section consisted of concentric two pipes; the inner pipe which was made of copper while the outer pipe was a Polyvinyl chlo-ride. Air was used as a working fluid in both hot and cold sides. A wide cold air flow rate range was covered from 3 to 36 m3/h which corresponds to Reynolds number (Re) range from 2811 to 31,335. The hot air flow rate was kept constant at 3m3/h. The temperature difference (ΔT) be-tween the inlet hot air and inlet cold air was adopted to be (20°C, 30°C, 40°C, and 50°C). The re-sults revealed that the higher Nusselt number (Nu) was at ΔT= 50°C and the thermal performance of the heat exchanger with the MF for all the arrangements was greater than the smooth heat exchanger. The highest and lowest friction factor was 1.033 and 0.0833 for the case 1 and 8, re-spectively, and the optimal performance evaluation criteria (PEC) was 1.62 for case 7 at Re = 2800. The Nu would be increased with a moderate increase in the friction factor by optimizing the arrangement of the MF. The two essential parameters that played an important role for in-creasing the PEC were the MF diameter and the MF arrangement along the axial length of the cold air stream.

Article
Numerical Investigation on heat transfer enhancement and entropy generation in a triangular ribbed-channel using nanofluid

Mohammad N. Dahham, M. A. Ahmed

Pages: 65-75

PDF Full Text
Abstract

In this paper, turbulent convective heat transfer in a triangular-ribbed chan-nel has been numerically investigated. SiO2-water with nanoparticles volume fraction of 4% and nanoparticles diameters of 30 nm is employed with Reyn-olds number ranging from 2000 to 8000. The governing continuity, momen-tum and energy equations in addition to low Reynolds number k-ε model have been transformed into body-fitted coordinates system and then solved using finite volume method. The effects of Reynolds number and rib heights on Nusselt number, pressure drop, thermal-hydraulic performance factor and entropy generation are presented and discussed. It is observed that the Nusselt number, pressure drop and thermal performance increase with in-creasing of Reynolds number and rib height. In addition, the highest perfor-mance factor can be obtained at Reynolds number of 6500 and rib height of 1.5 mm.

Article
Heat Transfer Enhancement Using Helical Pipes

Ajaj Helal Zgayer

Pages: 126-139

PDF Full Text
Abstract

The enhancement of laminar forced convection inside helical pipes is studied numerically and compared with plain pipes. The study is achieved numerically using the (Fluent-CFD 6.3.26) software program for solving the governing equations. The heat transfer coefficient and friction coefficient are calculated using the enhancement technique and compared with the plain tube. In this research the factors that affect the enhancement technique using helical pipes are studied, these factors are the ratio of (pitch /pipe length) (SL), Reynolds number and the heat flux applied to the external surface of the pipe. The results showed that there is an increasing in the heat transfer coefficient is related to the decreasing of (SL), increasing of Reynolds number and heat flux. The performance of the helical pipes is evaluated depending on the calculation of (Enhancement ratio), and it’s found that the enhancement ratio increases as Reynolds number increases and (SL) decreases. It is found that the best enhancement ratio was (200%) at (SR=0.05), (Re=2000),(Heat flux=3000W/m2).The results are compared with the literature and there is a good agreement.

1 - 6 of 6 items

Search Parameters

Journal Logo
Anbar Journal of Engineering Sciences

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.